Diagnostics
5.3 Diagnostics via Startdrive
5.3.4

Diagnostics information for the infeed unit

5.3.4.1

Calling the screen form

You can call up the screen form to display diagnostics information for an infeed unit as
follows:
1. In the project navigation, select menu "Infeed_x > Parameter".
The corresponding detailed view is displayed at the right.
2. In the secondary navigation, call menu "Diagnostics > xxx" (xxx stands for the name of
the particular detailed screen form)
The detailed view is updated.
5.3.4.2

Missing enables

Definition
The infeed does not change to the "Operation" state until all the enables are present. In the
"Missing enables" mask, the LEDs in the function view indicate which enables are still
missing. A red LED indicates that the appropriate enable signals are missing.
The bits of the missing enables (r0046) are displayed in the mask.
Figure 5-8
170
Display: missing inputs
Commissioning Manual, (IH3), 07/2016, 6SL3097-4AA10-0BP0
Commissioning with Startdrive