14.2

Cleaning hose rupture indicator (option)

The rotor stops and
cover again' appears.
If the position is not ideaI (the space for the roller to be fitted
should be quite far from the hose), move the rotor into the right
position by turning the
19.
Replace the roller (3) you have removed with its roller bracket and
screw tightly onto the rotor.
20.
Fit the front cover (1) and attach the 4 star-shaped screws (2) to the
dosing head (5). Screw the domed nut onto the 4th star screw again
and tighten it to provide a locking function.
21.
Press the Clickwheel.
'Hose change interval' menu appears.
ð The
'Revolutions' menu item in the 'Hose change interval'
22.
In the first
menu, you have the option of increasing or reducing the warning
time for the next hose change by changing the
are shown in thousands) - also refer to
[Clickwheel] to reset the warning time.
23.
Press the
'Reset interval now!' appears.
ð
[Clickwheel] again to complete the hose change.
24.
Press the
'Complete!' and a hand symbol appear. This is a reminder that
ð
the pump still needs to be stopped manually. If necessary, now
restart the pump using the
25.
If the pump hose was broken, now dismantle and clean the hose
rupture indicator (option).
WARNING!
Warning of unnoticed escape of feed chemical
After the hose rupture indicator has been triggered, any
residue of feed chemical may affect its function.
After the hose rupture indicator has been triggered,
clean and test it.
1.
Unscrew the hose rupture indicator using an SW 14 open-ended
spanner.
2.
Clean the hose rupture indicator with a suitable liquid - if possible
using water.
3.
Test the connected hose rupture indicator: fully immerse the
tapered section at the front in water.
ð The continuous display indicates a hose rupture.
4.
Thoroughly dry the hose rupture indicator.
ð The continuous display no longer indicates a hose rupture.
5.
Screw the clean and dry hose rupture indicator into the hole until
hand-tight and liquid-tight.
Maintenance
'Hose change - Step 3' - 'Insert roller and
[Clickwheel] .
'Revolutions' (they
'Service è Hose' .
[STOP/START] key.
79