Level Switch" Terminal; Hose Rupture Indicator" Socket (Dfm Input) - ProMinent DULCO flex Control-DFYa Operating Instructions Manual

Peristaltic metering pump
Table of Contents

Advertisement

"Analog" operating mode
"Auxiliary capacity" operating mode

9.3.2 "Level switch" terminal

1
P_BE_0016_SW
Fig. 13: Assignment on the pump
3
2
P_BE_0017_SW
Fig. 14: Assignment on the cable

9.3.3 "Hose rupture indicator" socket (DFM input)

2
3
P_DE_0009_SW
Fig. 15: Assignment on the pump
The pump capacity and/or number of revolutions can be controlled by a
current signal. The current signal is connected between pin 3 and pin 4.
Pin 1 and pin 4 must also be connected.
The pump works at a pre-set capacity if:
Pin 5 and pin 4 are connected to each other. At the same time, pin 1
n
and pin 4 must also be connected to each other. The auxiliary
capacity is factory-preset to maximum capacity.
There is a connecting option for a 2-stage level switch with pre-warning
and limit stop.
Electrical interface
Data
3
Voltage with open contacts
Input resistance
Control via:
2
potential-free contact (load: 0.5 mA at 5 V) or
n
semiconductor switch (residual voltage < 0.7 V)
n
Pin
1
2
3
1
There is an option to connect a hose rupture indicator.
Electrical interface
Data
1
Voltage with open contacts
Input resistance
Control via:
4
potential-free contact (load: 0.5 mA at 5 V) or
n
Function
Earth GND
Minimum pre-warning
Minimum limit stop
Insert the cable which runs in the metallic pump foot
from the hose rupture indicator on the side with the
sockets into the "Hose rupture indicator" socket.
Installation, electrical
Value Unit
5 V
10 kΩ
3-wire cable
black
blue
brown
Value Unit
5 V
10 kΩ