Overview of equipment and control elements

5.2.4 Functional and Fault Indicators

Fault indicator (red)
Warning indicator (yellow)
Operating indicator (green)

5.2.5 "External control" terminal

5.2.6 "Level Switch" terminal

18
The fault indicator lights up if the liquid level in the chemical feed container
falls below the second switching point of the level switch (20 mm residual
filling level in the chemical feed container).
This LED flashes in the event of an undefined operating mode.
The warning indicator lights up if the fluid level in the chemical feed con‐
tainer falls below the first switching point of the level switch.
The operating indicator lights up if the pump is ready for operation and
there are no fault or warning alerts. It goes out quickly as soon as the
pump has performed a stroke.
The "external control" terminal is a five-pole panel terminal.
It enables the following functions and operating modes to be used:
Pause
n
External contact
n
Auxiliary frequency (external frequency changeover)
n
The two- and four-pole cables used to date can continue to
be used. The "Auxiliary frequency" function can, however,
only be used with a five-pole cable.
A 2-stage level switch with pre-warning and end switch-off can be con‐
nected.