14.1. Integrated UPS (optional)

The DLT-V72 is optionally available with an integrated UPS. The battery pack of the UPS
is located in the battery pocket of the device.
WARNING

14.1.1. Battery pack specifications

Battery pack (Lithium-Ion technology)
Bridging time
Operating temperature
Charging time
Charging temperature
Storage temperature
Maximum output power
Battery voltage
Battery capacity
DLT-V72 Series User Manual V2.70

Fig. 14.1: Battery pocket with UPS DLT-V72

Personal injury due to short-circuit, fire, chemical burns,
toxic substances
DLT-V72 devices with integrated UPS contain battery packs.
These can ignite if handled or stored improperly (risk of fire),
cause chemical burns or release toxic substances.
1. Use care when handling battery packs.
2. Please observe manual section 2.3 Battery pack safety .
The integrated UPS can bridge an interruption of the main
supply for typically 20 minutes. Requirement: The battery
pack is fully charged.
-30 to +50 °C
4 h (fully recharge a completely discharged battery pack).
-10 to +50 °C (ambient temperature)
-30 to +60 °C
40 W
7,2 V
2000 mAh