11.

Integrated UPS (optional)

DLT-V83 industrial PCs are optionally available with an integrated Uninterruptible Power Supply
(UPS). The lithium-ion battery packs of the UPS are located in the cable cover of the DLT-V83.

Fig. 11.1: Cable cover with integrated battery packs for the UPS

Personal injury from battery packs: Short-circuit, fire, chemical burns, toxic substances.
The integrated UPS battery packs in the cable cover of the DLT-V83 can ignite if handled
improperly (risk of fire), cause chemical burns or release toxic substances.
Handle the cable cover carefully.
Do not allow water or other liquids to come into contact with the device (exercise particular
caution with corrosive liquids).
Ensure that no liquids or foreign bodies get into the cable cover.
Provide sufficient ventilation.
Do not allow the device to come into contact with fire or operate it close to sources of heat
or fire, open flame or heaters.
Observe the specific IP protection class.
Only use the DLT-V83 within the permitted temperature and humidity range.
Do not subject it to strong impacts and vibrations that exceed what is specified by the
class 5M3/5M2 (DIN EN 60721-3-5).
Advantech-DLoG
WARNING
DLT-V83 Series Manual V1.50
Integrated UPS (optional)
Page 73 of 122