Replacing The Integrator Zoom Adjustment Knob - Christie Crimson Series Service Manual

Hide thumbs Also See for Crimson Series:
Table of Contents

Advertisement

Move the liquid cooling module aside without disconnecting the hoses.
4. Disconnect the color sensor board harness J82.
5. Remove the four screws securing the fold mirror assembly.
6. Remove the four screws securing the fold mirror and remove it.
7. Replace the fold mirror, if required.
8. To re-install, repeat these steps in reverse order.
The reflective coating side must be on the side closest to the springs.
9. Optimize the integrator focus and zoom. (on page 22)
10. Adjust the fold mirror. (on page 23)

Replacing the integrator zoom adjustment knob

The knob is used to adjust the integrator zoom lens.
1. Remove the fold mirror (on page 83).
2. Loosen the adjustment knob lock screw.
Crimson Service Guide–Crimson HD25, Crimson WU25, Crimson HD31, Crimson WU31, Mirage HD25, Mirage WU25
020-102733-02 Rev. 1 (01-2020)