COMMUNICATION MAP
38LS XMIT/RECV CHECK
PAGE
11 OF
20
052
- Check for the correct
dB
level
going
into
the the World Trade
line plate.
Connect
the
dB
meter
between
TPl,
'Telephone
Line
1', (MIM
827) (which is a direct line
to
TBl-9)
and TB2, 'Telephone Line
2' (MIM 827) (which is a
direct
line to TBl-8).
Is the dB level correct?
Y N
A
A
053
- Check for the correct dB level
at
the
J140 connector on the
external cable (MIM 869, probe
point H).
Connect the dB
meter
between
J140-l3
'- Telephone Line 1',
and
J140-14
'Telephone
Line
2'.
Is the dB level correct?
Y N
054
Defective external cable.
055
- Defective
internal cable that
connects the World Trade
line
plate to Jl40.
A
A
MAP 3011-11
056
Note:
If
you
following dB
dB
meter
or
cannot
verify the
measurements
(bad
such), seeing that
Carrier
Det'
is
active
33LS
is
verifies
that
the
receiving the signal.
Probe A-D7B12, '-
Carrier
(MIM 869, probe point B).
Det'
Up
light: O-ff
Down light: On
Are the lights correct?
Y N
057
Power off.
Disconnect
the internal cable
from
the
communications
MPU
card at connector A-E5-J01.
At
the
POl
connector ON THE
INTERNAL
CABLE
check
continuity
between
POI-07,
'Data
Tip',
(MIM
8'9, probe
point E), and the
line
plate
connector
A08 (MIM 869, probe
point F).
connector
ON
THE
At the POI
INTERNAL
CABLE
check
POl-23,
continuity
between
'Data
Ring',(MIM
869,
point
E),
and the line
connector B08 (MIM 869,
point F).
probe
plate
probe
Is continuity good?
Y N
1 1
2 2
A A
B C
058
Defective
cable between the
Communications MPU card
and
the World Trade line plate.
EC840874
PEC839787
MAP 3011-11