A A
G H
1 1
1 1
COMMUNICATIONS MAP
EIA WRAP ERROR MAP
PAGE
12 OF
12
072
The
internal
cable
de-fect i ve.
073
is
Probe
the
extra
'Transmitted'
line at probe point
D.
Up
light: On or Pulsing.
Down light: On or Pulsing.
Are the lights correct?
Y N
07
l
t
Defective
communications
MPU
card (A-E5)(MIM 811).
If
a
'Ros
Patch'
cable
is
connected to the card,
GO TO MAP 0600, ENTRY POINT A.
075
- Probe
the
extra
'Transmitted'
line at probe point C.
Up
light: On or Pulsing.
Down light: On or Pulsing.
Are the lights correct?
Y N
076
The logic board is defective.
077
- Probe
the
extra
'Transmitted'
line at probe point B.
Up
light: On or Pulsing.
Down light: On or Pulsing.
Are the lights correct?
Y N
A A
J
K
A A
J K
MAP 3019-12
078
The
EIA
line adapter card is
defective (A-D7)(MIM 823).
079
- Probe
the
extra
'Transmitted'
line at probe point A.
Up
light: On or Pulsing.
Down light: On or Pulsing.
Are the lights correct?
Y N
080
The logic board ;s defective.
081
- Defective
communications
MPU
card (A-E5)(MIM 811).
If
a
'Ros
Patch'
cable
is
connected to the card,
GO TO MAP 0600, ENTRY POINT A.