Distributed data system programmable data station maintenance analysis procedures
Hide thumbs Also See for 5280:
Table of Contents

Advertisement

E
2
COMMUNICATIONS MAP
NON AUTO ANSWER
PAGE
3 OF
S
010
See 38LS switch setting chart in
MIM 813,81S, or 817 to determine
which
switches
should
be
on.
(If
using
programable
attenuation,
the
38LS
card
should have been set for 0 db.
Are
all switches on the 38LS line
adapter card set correctly?
Y N
011
Set correctly
and
rerun
the
test.
012
Connect
khe
dB
meter
between
A-D7DOS
'SW
Data
Xmit'
and
A-D7DOS
'Gnd'.
The
DB
level
should be equal to the level set
in
the
38LS
line adapter card
switches.
Note:
A
quick way to indentify a
communications MPU card that has
programmable attenuation
is
as
follows:
If
there
are
4
transmit
level attenuators on the lower
left
corner
of
the
communications MPU
card,
the
card
has
programmable
attenuation(MIM 811).
Is the db level correct?
Y N
4
F G
G
MAP 3013-3
013
-
Power off.
-
Remove the 3SLS card.
-
Use the
CE
meter
on
the
RXI
scale
to measure the resistance
to a ground pin.
A
short
Wlll
read less than 20 ohms.
Measure
A-D7D05,
'SW
Data
Xmit',
to
A-D8D08,
'Gnd'
(MIM 867, probe
point C).
Is the line grounded?
Y N
014
-
Defective
38LS
line
adapter
card (A-D7)(MIM (12).
OlS
Remove
the
communications
MPU
card (A-ES)(MIM (11)
Is the line grounded?
Y N
016
Defective
communications
MPU
card (A-ES)(MIM 811).
If
a
'Ros
Patch'
cable
;5
connected to the card,
GO TO MAP 0600, ENTRY POINT A.
017
Defective
communications
card (A-ES)(MIM 811).
MPU
If
a
'Ros
Patch'
cable
;5
connected to the card,
GO TO MAP 0600, ENTRY POINT A.
ECS40874
PEC839787
MAP 3013-3