IBM 5280 Manual page 85

Distributed data system programmable data station maintenance analysis procedures
Hide thumbs Also See for 5280:
Table of Contents

Advertisement

A
K
I
2
DATA ENTRY MAP
A-AI DISPLAY
PAGE
13 OF
13
066
Power off.
Disconnect
the
Display
connector P20 (MIM 217).
-
Power
on.
Check
to
see
that
the
Brightness Control and Contrast
Control are fully clockwise.
-
Probe
A-Al-TPlO,
'+
Video
Dri ve'
(MIM 200, 217).
Up
light: On
Down light: On
Are the lights correct?
Y N
1
5
067
Probe A-A3B05,
'1 MHz
clock'
(MIM 531).
Up
light: On
Down light: On
Are the lights correct?
Y N
068
For
the line probed in the
previous step.
Up
light: Of-f
Down light: On
Are the lights correct?
Y N
069
- Defective Diskette/Main
MPU
card
(A-CI)
(MIM
303) .
If a
'ROS Patch' cable is
connected to the card,
GO TO MAP 0600,
ENTRY POINT A.
A A A
L 1' 1 N
A A
M N
MAP 1010-13
070
-
Power off.
-
Set the CE meter to
the
RXI
scale.
C0~~eGt
the
positive lead to
A-A3B 05,
'1 MH z
clock',
and
the negative lead to ground.
Is the meter reading 30 ohms or
above?
Y N
071
-
Leave
the
meter connected
as in the previous step.
-
Use the net list (MIM 531).
Remove
each
card
in
the
net,
one
at a time, until
the meter reads 30 ohms
or
above.
-
Replace
removed.
the
last
card
If
all
cards
in
the net
have been removed
and
the
meter
reading
is
still
below
30
ohms,
suspect a
ground on the Logic Board.
072
- Defective
Diskette/Main
MPU
card (A-Cl)
(MH1 303).
If
a
'ROS
Patch'
cable is
connected to the card,
GO TO MAP 0600, ENTRY POINT A.
073
Connect
the
CE
meter
from
A-Al-TP-12,
'Bri ghtness
Control', to ground (MIM 217).
The voltage should change
from
a
to
+5 Vdc as the Brightness
Control is turned clockwise.
Is the voltage correct?
Y N
EC340874
PEC339787
1 1
4 4
A A
P
Q
MAP 1010-13