A
3
COMMUNICATIONS MAP
EIA WRAP ERROR MAP
PAGE
8 OF
12
039
- Probe
the extra 'Received' line
at probe point A.
Up
light: On or PUlsing.
Down light: On or Pulsing_
Are the lights correct?
Y N
1
040
THE SYMPTOMS INDICATE
THAT
THE
EXTRA
'RECEIVED'
LINE IS STUCK
AT ITS ACTIVE LEVEL.
Remove the wrap connector.
Note:
The
'Received'
line
displayed may change with
the
wrap
connector
removed.
Ignore this byte for now.
- Probe
the extra 'Transmitted'
line at probe point F.
Up
light: On
Down light: Off
Are the lights correct?
Y N
041
THE SYMPTOMS INDICATE THAT THE
EXTRA
'RECEIVED'
PICKING
UP
THE
LINE.
- Reinstall
the
connector.
LINE
IS
'RECEIVED'
wrap
- Probe
the
extra 'Received'
line at probe point B.
Up
light: Off
Down light: On
Are the lights correct?
Y N
o
9
V W X Y
X Y
MAP 3019-8
042
- The logic board is defective.
OR - - - - -
The EIA line Adapter
card
is
defective (A-D7)(MIM 823).
- - - - - OR - - - - -
Defective
communications
MPU
card (A-E5)(MIM 811)
- If
a
'Ros
Patch'
cable
is
connected to the card,
GO TO MAP 0600, ENTRY POINT A.
043
- Probe
the extra 'Received' line
at probe point C.
Up
light: On
Down light: Off
Are the lights correct?
Y N
I
044
- The EIA line Adapter
card
is
defective (A-D7)(MIM 823).
045
- Probe
the extra 'Received' line
at probe point D.
Up
light: On
Down light: Off
Are the lights correct?
Y N
EC840874
PEC839787
9
9 A
Z A
MAP 3019-8