F G H
222
BASE
~lAP
PARITY CHECK
PAGE
3 OF
4
010
Defective Diskette/Main
MPU
car d (A- C
1)
(
M
I
M
303).
If
a
'Ros
Patch' cable is
connected to the card,
GO TO MAP 0600,
ENTRY POINT A.
011
GO TO STEP 012,
ENTRY POINT B.
012
(ENTRY POINT B)
- Power Of-f.
Check the control
line(s)
that
match
the probe light condition
for a ground.
- Use the C.E.
Voltmeter
set
to
the RXI range.
Connect
the
C.E.
voltmeter to
the probe point for the
failing
control line(s).
Does
the
meter
have
a
5
ohm or
less reading?
Y N
013
Power Off.
Remove the
following
feature
MPU
card(s)
(if
installed)
(MIM 501).
Feature
Location
Printer
A-D5
Communications
A-E5
Power On.
Does Power On Checkout fail with
a Parity Check?
Y N
D
J
K L
2
NAP
0532-3
014
- Install
the
feature
MPU
card(s), one
at
a
time,
until the error ocurrs.
If
a 'Ros Patch' cable is
connected to the card,
GO TO MAP 0600,
ENTRY POINT A.
015
Defective Diskette/Main
MPU
card (A-Cl) nlIM 303) or the
Keyboard/Display
MPU
card
(A-A 1) nlI M 200).
-
If
a
'Ros
Patch' cable is
connected to the curd,
GO TO f'lAP 0600,
ENTRY POINT A.
016
- Use MIM 531
for
the
failing
line net.
- Remove
all
cards in the net,
one at a time, until the meter
reading is 100 ohms or more.
If
all
cards
have
been
removed, and the meter reading
is still zero, check the logic
board for a ground.
017
Defective Feature
Main
Storage
card (A-B5) (MIM 403).
-
-
-
-
-
OR -
-
-
Defective Diskette/Main MPU card
(A-Cl) (MIM 303).
If
a
'Ros
Patch'
cable
is
connected to the card,
GO TO MAP 0600, ENTRY POINT A.
ECS40S74
PECS397S7
J
K L
MAP 0532-3

Advertisement

Table of Contents
loading

This manual is also suitable for:

5285