Distributed data system programmable data station maintenance analysis procedures
Hide thumbs Also See for 5280:
Table of Contents

Advertisement

A
X
1
3
A
DATA ENT RY
t'1AP
Y
1
MSR
3
PAGE
14 OF
14
100
Power off.
Set
the
CE meter to the RXI
scale.
Connect the positive lead
to
A-B2B07,
Extended
Sense
Bit', and the
negative
leud
to ground.
Is the meter reading 30 ohms or
above?
Y N
101
102
Leave
the
meter connect0d
as in the previous step.
Use the net list (MIM 531).
Remove
each
card
in
the
net,
one
at a time, until
the meter reads 30 ohms
or
above.
Replace
the
last
card
removed.
If all the cards in the net
have
been
removed and the
meter
reading
is
still
below 30
ohms,
suspect
a
ground on the Logic Board.
Defective Keyboard/Display
MPU
Card
(A-AI)
(MIM
200,
501).
If a
'Ros
Patch'
cable
is
connected to the card,
GO TO MAP 0600, ENTRY POINT A.
103
Pass
the test card through the
reader
several
times
while
observing the display.
Is an error message presented
on
the display each time?
Y N
A B
Z A
A B
Z A
MAP 1030-14
104
The
test
card
passed
through
should
be
the
reader
upside down to cause an error
condition on purpose.
Pass
the
card
through
the
reader upside down,
so
that
the
magnetic stripe will not
be read by the reader.
Is any error message
presented
on the display?
Y N
105
106
Defective
MSR
card (A-Bl>
(MIM SOl, 771>.
GO TO MAP 0100, ENTRY POINT A.
107
Defective MSR card (A-S1)
501, 771).
(MIM
EC839787
PECS39661
MAP 1030-14