IBM 5280 Manual page 241

Distributed data system programmable data station maintenance analysis procedures
Hide thumbs Also See for 5280:
Table of Contents

Advertisement

8
2
COMMUNICATIONS MAP
COMM PROBLEMS
PAGE
3 OF
4
002
- Run
the
MDI
several
times to
show up intermittent problems.
Does the MDI run without error?
Y N
003
- Correct any problems indicated
by MDls.
004
Is
the
DDSA
line
adapter
card
installed?
Y N
OOS
- Probe
A-D7B04,
'-
Rate
Select'.
- For full rate the lights
will
be:
Up
light: Off
Down light: On
-
For
half rate the
l~ghts
be:
Up
light: On
Down light: Off
Are the lights correct?
Y N
006
will
- Defective communications MPU
card (A-ES)(MIM 811).
C D
If a 'Ros
Patch'
cable
is
connected to the card,
GO TO MAP 0600,
ENTRY POINT A.
A C D
2
007
MAP 301S-3
Probe
A-D7B13,
'- Data Set
Rea dy' .
Up
light: Off
Down
light:
On
Are the lights correct?
Y N
OOS
- Defective communications
MPU card (A-ES)(MIM 811).
If a 'Ros Patch' cable
is
connected to the card,
GO TO MAP 0600,
ENTRY POINT A.
009
GO TO MAP OSOO,
ENTRY POINT A.
010
GO TO MAP 0800, ENTRY POINT A.
011
The
9
MHZ
oscillator
is
essential to the
communications
MDI
routines because it is used
for timing.
If
the
oscillator
is
not
active,
the diagnostiC
routine will not end.
- This problem is not detected
by
any diagnostic.
- Probe A-ESBOS '9 MHZ'.
Up
light: On or Pulsing.
Down light: On or Pulsing.
Are the lights correct?
Y N
ECS40874
PECS397S7
4 4
E F
MAP 301S-3

Advertisement

Table of Contents
loading

This manual is also suitable for:

5285