IBM 5280 Manual page 79

Distributed data system programmable data station maintenance analysis procedures
Hide thumbs Also See for 5280:
Table of Contents

Advertisement

M P
6 6
DATA ENTRY MAP
A-AI DISPLAY
PAGE
7 OF
18
020
Defective
Diskette/Main
MPU
card (A-Cl)
(~lIM
303).
If a
'ROS
Patch'
cable
is
connected to the card,
GO TO MAP 0600. ENTRY POINT A.
021
Probe
A-A3B05,
(HIM 531).
'1
MHz clock'
Up
light: On
Down light: On
Are the lights correct?
Y N
t
022
For the line
probed
in
the
previous step,
Up
light: Off
Down light: On
Are the lights correct?
Y N
023
- Defective Diskette/Main MPU
card (A-Cl) (MIM 303).
If
a
'ROS Patch' cable is
connected to the card,
GO TO MAP 0600,
ENTRY POINT A.
R
MAP 1010-7
024
- Power off.
- Set the CE
meter
to
the
RXI
scale.
Connect
the
positive
lead to
A-A3B05,
'1
MHz clock', and the
negative lead to ground.
Is the meter reading 30
ohms
or
above?
Y N
025
- Leave
the meter connected as
in the previous step.
- Use the net list
(MIM
531).
Remove
each card in the net,
one
at
a
time,
until
the
meter reads 30 ohms or above.
- Replace
the
last
card
removed.
- If all cards in the net
have
been
removed
and
the meter
reading
is
still
below
30
ohms, suspect a ground on the
Logic Board.
026
- Defective
Diskette/Main
MPU
car d (A- C
1)
(
M I M 303).
If
a
'ROS
Patch'
cable
is
connected to the card,
GO TO MAP 0600, ENTRY POINT A.
EC840874
PEC839787
Q R
MAP 1010-7