6
DATA ENTRY MAP
A-El DISPLAY
PAGE
8 OF
10
044
Probe
A-E3D02~
'1
MHz
Clock'
(MIM 531).
Up
light: On
Down light: On
Are the lights correct?
Y N
045
For
the
line
probed in the
previous step,
Up
light: Off
Down 1 i ght: On
Are the lights correct?
Y N
046
Failing
Diskette/Main
MPU
Card (A-Cl) (MIM 303).
-
If
a
'ROS Patch' cable is
connected to the card,
GO TO MAP 0600,
ENTRY POINT A.
047
The '1
MHz
Clock'
line
is
failing.
Suspect
a shorted
net.
Use the net
list
(MIM
531) to isolate the problem.
OR - - - - -,
Failing
Diskette/Main
MPU
Card (A-Cl)
(MIM 303).
-
If
a
'ROS
Patch'
cable is
connected to the card,
GO TO MAP 0600, ENTRY POINT A.
y
MAP 1011-8
048
Power off.
Remove
the
terminating
resistor.
-
Set
the
CE
meter
to the RXI
scale.
Disconnect
POI
on
A-El
(MIM
201, 203, 227).
Connect the positive end
~f
the
met e r
t
0
A-
E 1-
P
0
1-
4 ,
,
+
V ;
de
0
Drive', and the
negative
lead
to ground (MIM 201, 203, 227).
The
meter
should
read in the
range of 30 ohms to 150 ohms.
Is the meter reading correct?
Y N
049
-
Use MIM 227 to trace
the
'+
Video
Drive'
line for opens
or grounds.
-
OR - -
-
GO TO THE 5281 OR
5282
DATA
STATION
DATA ENTRY MAP 1000,
ENTRY POINT A.
050
-
Failing
Data
Station
Adapter
Car d (A- E
I)
(
M 1M 501).
EC840874
PEC839787
Y
MAP 1011-8

Advertisement