Q STU
666 6
COMMUNICATIONS MAP
EIA WRAP ERROR MAP
PAGE
7 OF
12
030
Remove the
communications
MPU card.
-
If the short goes away the
communications MPU card is
bad.
If
the
short
present,
the
is defective.
is
still
logic board
If a 'Ros Patch' cable
is
connected to the card,
GO TO MAP 0600,
ENTRY POINT A.
031
- Check
each
FRU to find the
failure.
The internal cable.
The communications MPU card.
- The logic board.
If a 'Ros
Patch'
cable
is
connected to the card,
GO TO MAP 0600,
ENTRY POINT A.
032
Remove
the parts listed below
one at
a
time
in
the
order
given
until
the
short
goes
away.
The last
part
removed
is defective.
The internal cable.
The communications MPU card.
- The EIA line adapter card.
If the short is still present,
the logic board is defective.
If
a
'Ros
Patch'
cable
is
connected to the card,
GO TO MAP 0600, ENTRY POINT A.
033
The land pattern is open on
the
logic board.
M N P
666
f'1AP 3019-7
034
- Power off.
- Remove
the EIA line adapter
card.
- Use the CE meter on the
RXI
scale
to
measure
the
resistance to a ground
pin.
A
short will read less than
20
ohms.
Measure
the
'Received'
line
at
probe
point
B.
Is the line grounded?
Y N
035
036
The
EIA line adapter card
is
defective
(A-D7)(MIM
823) .
- Remove
the
communications
MPU card.
- If the short goes away,
the
communications
MPU
card is
defective.
If
the
short
is
still
present, the logic board
is
defective.
If
a
'Ros
Patch' cable is
connected to the card,
GO TO MAP 0600,
ENTRY POINT A.
037
- The land pattern
is
open
on
the logic board.
038
Defective
communications
MPU
card (A-E5)(MIM 811).
If
a
'Ros
Patch'
cable
is
connected to the card,
GO TO MAP 0600, ENTRY POINT A.