IBM 5280 Manual page 246

Distributed data system programmable data station maintenance analysis procedures
Hide thumbs Also See for 5280:
Table of Contents

Advertisement

C E F
122
COMMUNICATIONS MAP
AUTO ANSWER
PAGE
4 OF
7
011
- Measure
Relay' .
A-D8B03
'Transfer
Is
the
signal
approximately
-2.7 Vdc?
Y N
012
-
Defective
adapter
812).
013
3SLS
line
card
(A-D7)(MIM
Defective
World
Trade line
plate.
014
-
Check
for
2100
Hz
between
A-D7DC5
, , r.
_.a. ....
...,....,'-""1 ...
0
A-D7DOS 'GND'.
T~_'
• 't'"
--....I
a l i U
Is 2100 Hz
present
during
3.5
seconds?
Y N
015
Defective
3SLS line adapter
card (A-D7)(MIM 812).
016
017
Defective
World
Trade
plate.
line
Does the answering tone stop after
3.5 seconds?
Y N
5 5
H J
MAP 3016-4
A-DSB03
'Transfer
Relay'
signal
levels:
On: -2.7 Vdc
Off: -4.5 Vdc
The
38LS
should
activate
the
'Transfer
Relay'
when
'Current
Detection
l'
and
'Current
Detection
2'
are
activated
(together three times),
and
when
the machine is in data mode.
Use
CE
tool
'intercom'
or
'dB
meter'
The 3SLS should
send
a
2100
Hz
tone
when
answering
a
call
automatically.
EC840874
PEC839787
MAP 3016-4

Advertisement

Table of Contents
loading

This manual is also suitable for:

5285