IBM 5280 Manual page 217

Distributed data system programmable data station maintenance analysis procedures
Hide thumbs Also See for 5280:
Table of Contents

Advertisement

5285 COMMUNICATIONS MAP
AUTO ANSWER COUPLER
PAGE
1 OF
13
ENTRY POINTS
FROM
I
ENTER THIS MAP
-------+----------------------
MAP
I
ENTRY
PAGE
STEP
NUMBER
I
POINT
NUMBER
NUMBER
-------+----------------------
3010
I
A
1
001
001
(ENTRY POINT A)
USE
THIS
MAP TO FIND PROBLEMS IN
THE LOCAL 38LS INTEGRATED MODEM OR
LOCAL
AUTO
ANSWER
TYPE
COUPLER
(CBS) BY USING ANOTHER TELEPHONE.
Before
continuing,
verify that
the connections from
the
modem
to
the
couple~
are correct (see
color code chart on the right).
Ensure that the test switch
(if
present) on the CBS type coupler
is in the normnl position.
When
measuring
EIA
levels,
select
the
60 Vdc scale on the
CE
meter
to
prevent
meter
damage.
Place the
+/-
DC switch
on
the
CE meter to the
+
DC position.
The
meter lead connections will
be
indicated
by
the
MAP
questions
so
that the expected
signal will deflect the meter in
a positive direction.
Place the telephone(s) on hook.
Some telephones have a Talk/Data
(Step 001 continues)
Copyright IBM Corp 1980
MAP 3012-1
EXIT POINTS
EXIT THIS MAP
I
TO
---------------+--------------
PAGE
STEP
I
MAP
ENTRY
NUMBER
NUMBER
I
NUMBER
rOINf
---------------+--------------
3
009
0600
A
6
039
0600
A
7
055
0600
A
9
067
0600
A
11
092
0600
A
10
079
0600
A
11
087
0600
A
4
026
0600
A
7
050
0600
A
***
LINE NAMES
AND
COLOR
CODES.
***
Lines
are
listed
from
left-to-right as they appear
when
looking at the coupler.
'Switch Hook'
=
Red
'Signal Ground'
=
Gray
'Data Modem Ready'
=
Yellow
'Coupler Cut Through'
=
Brown
'Off Hook'
=
Blue
'Ring Indicate'
=
Violet
'Data Tip'
=
White
'Datfi Ring'
=
Black
NOTES:
'+
EIA
levels' are +3 to +25 Vdc
when measured to 'Signal Ground'.
'- EIA levels' are -3 to
-25
Vdc
when measured to 'Signal Ground'.
All
above
coupler
connections
except
'Data Tip' and 'Data Ring'
have active levels which are at
'+
EIA levels.'
EC840S74