IBM 5280 Manual page 128

Distributed data system programmable data station maintenance analysis procedures
Hide thumbs Also See for 5280:
Table of Contents

Advertisement

B
1
DATA ENTRY MAP
MSR
PAGE
2 OF
14
002
There
can
be
up
to
three
magnetic
stripe
readers
attached
to
the
MSR
control
card.
Each MSR is attached
to
a partition in storage which is
the
same
one
used
by
its
associated
keyboard.
These
partitions/stations are
numbered 0, 1, and 2.
The
signal
lines
to and from
the MSR control card are common
to
all
three
stations.
The
only
exceptions
are
the
'Photocell'
and
'Raw
Data'
inputs coming into plugs on the
side
of
the
card
from
the
reader stations.
Each of these
plugs
works
with
a
specific
par tit ion-
0
n 1 y .
- To
check
each
station
for
correct
operation
load
'MSRTEST' from
the
diagnostic
diskette
at
the
associated
keyboard
station
and pass the
test
MSR
card
(P/N
8331402)
through
the
reader (MIM 751).
The
correct
message
which
should appear on the screen is:
BBB0123456789BACDE0123456789.
- All three stations need not
be
used on any given system.
Is
station
0
'yes'
if
no
this station)?
Y N
6
C D
working
(answer
MSR
is
attached to
D
MAP 1030-2
003
Disconnect
the
connector
A-BlJOl (MIM 773).
Check
for
+5
Vdc
A-Bl-JOl-8
to
ground
A-Bl-JOl-7 (MIM 785).
at
from
at
Is +4.5 to +5.5 Vdc present?
Y N
004
Defective
MSR
card
(A-Bl)
(MIM 501, 773).
005
Check
for
-5
Vdc
A-Bl-JOI-I0
to
ground
A-BI-JOI-9 (MIM 785).
-from
at
Is -4.5 to -5.5 Vdc present?
Y N
I
006
Defective
MSR
card
(A-Bl)
(MIM 501, 773).
007
Plug the connector back
in
at
A-Bl-JOl.
With
a
CE meter, check for +2
Vdc to +3 Vdc from A-BITP-12 to
frame ground (MIM 773).
Is the voltage correct?
Y N
3
E
008
Defective
Reader
(MIM 761).
EC839787
Assembly
PEC839661
MAP 1030-2

Advertisement

Table of Contents
loading

This manual is also suitable for:

5285