Distributed data system programmable data station maintenance analysis procedures
Hide thumbs Also See for 5280:
Table of Contents

Advertisement

B
DATA ENTRY MAP
2
A-Al KEYBOARD
PAGE
3
OF
11
002
Note:
The
System
must
be
dedicated
to
maintenance
at
this time.
- Power off.
- Ensure
that
all
Diskette
locking levers are open.
Power on.
Wait at least
30
seconds
for
the
condition code table to be
displayed
on
Data
Station
0
(t-lIM 931).
Is there a Scan code for Keyboard
o
displayed
in
line
1
of the
condition code tables (MIM 93l)?
Y N
1
003
(ENTRY POINT B)
- Probe the '100 Hz Clock' line
at A-A4B02 (MIM 531).
Up
light: On
Down light: On
Are the lights correct?
Y N
004
For the line probed in
the
previous step:
Up
light: Off
Down light: On
Are the lights correct?
Y N
I 4
C D E F
E F
MAP 1020-3
005
Defective
Diskette/Main
MPU
card (A-Cl) (MIM 303).
If a
'Ros
Patch'
cable
is
connected to the card,
GO TO MAP 0600, ENTRY POINT A.
006
Power off.
Set
the
CE
meter
to the RXl
scale.
- Connect
the
positve
lead
to
A-A4B02,
'100
Hz
Clock', and
the negative lead to ground.
Is the meter reading 30
ohms
or
above?
Y N
007
- Leave
the meter connected as
in the previous step.
Use the net list (MIM 531).
Remove each card in the
net,
one
at
a
time,
until
the
meter reads 30 ohms or above.
Replace
the
last
card
removed.
- If
all
the cards in the net
have
been
removed
and
the
meter
reading is still below
30 ohms, suspect a ground
on
the Logic board.
008
Defective
Diskette/Main
MPU
card (A-Cl) (MIM 303).
If
a
'Ros
Patch'
cable
is
connected to the card,
GO TO MAP 0600, ENTRY POINT A.
EC840874
PEC839787
MAP 1020-3