IBM 5280 Manual page 134

Distributed data system programmable data station maintenance analysis procedures
Hide thumbs Also See for 5280:
Table of Contents

Advertisement

Y Z
7 7
DATA ENTRY MAP
MSR
PAGE
8 OF
14
050
-
GO
TO
THE 5281 OR 5282 DATA
STATION MAP 1030, ENTRY POINT
A.
051
-
Probe A-BI-TP-07,
' -
Raw
Data
MSR A'
(t-1If'1
773, 787).
Up
light: On
Down light: On
Are
the lights correct as a test
card is passed through the reader
(MIM 751)?
Y N
052
- Power Off.
-
Disconnect the connector from
JI03 of the
cable
connector
panel
(MIM 787).
-
Set
the
CE meter to the RXI
scale.
- Measure the
resistance
from
the
back
panel
connector
(Jl03) pin 17, '-Raw Data MSR
Af,
to
frame
ground
(MIM
787) .
The
meter should read in the
range of 50 to 100 ohms.
Does the meter read between
50
to 100 ohms?
Y N
A A
A B
053
Use
MIM
787
to trace the
'-Raw Data MSR
A'
line
opens or grounds.
-
OR
for
-
Defective
MSR
card (A-Bl)
<tHM SOl, 773).
V A A
6 A B
f"lAP
1 030-8
054
-
GO TO THE 5281 OR 5282 DATA
055
STATION
POINT A.
MAP
1030,
ENT RY
GO TO PAGE 4, STEP 019,
ENTRY POINT B.
056
Is
station
2
'yes' if no NSR
this station)?
Y N
working
(answer
is
attached
to
1
057
-
Probe A-Bl-TP04,
'+ Photocell
MSR
B'
(remote)
(MIM
773,
787) .
Up
light: O·ff
Down light: On
Are the lights correct?
Y N
058
- Power Off.
-
Disconnect
the
connector
from
JI03
of
the
cable
connector panel (MIM 787).
-
Set the CE meter to the RX1
scale.
- Neasure the resistance from
the
back
panel
connector
(JI03) pin 18,
'+
Photocell
MSR
B'
(remote), to frame
ground (MIN 787).
-
The meter
the
range
ohms.
should
of
50
read
to
in
100
Does the meter
read
between
50 to 100 ohms?
Y N
o
9 9 9
A A A A
C D E F
EC839787
PEC839661
MAP 1030-8

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 5280 and is the answer not in the manual?

This manual is also suitable for:

5285