IBM 5280 Manual page 190

Distributed data system programmable data station maintenance analysis procedures
Hide thumbs Also See for 5280:
Table of Contents

Advertisement

S
5
DISKETTE MAP
INTER LED
PAGE
6 OF
046
More than one 'Drive In
Use'
LED
fail?
Y N
047
Is
the
failing
'Drive In Use'
LED in the controller?
Y N
048
-
Probe
A-CIB08
A-C2D05 (4COO)
(4800)
o,r
File
In
Use'
for the failing LED on
the logic board (MIM 501).
Up
light: On
Down light: Off
Are the lights correct?
Y N
I
049
I I
- Leave
the
probe
on
the
previous point.
7 7
Up
light: Off
Down light: On
Are the lights correct?
Y N
050
Defective Diskette/Main
MPU
card
(A-Cl)
(MIM
303) •
-
If
a
'Ros Patch' cable
is
connected
to
the
card
t
GO TO MAP 0600,
ENTRY POINT A.
T U V W
V W
MAP 2280-6
051
052
There is an open or
short
in
this
line,
use
MIM
313 and
Logic
Diagram
LDOl-3
to
isolate the failure.
-
IPL
the
system with Diagnostic
Diskette 1.
Do all the
'Drive
In
Use'
LEDs
turn off?
Y N
053
- Probe
A-CIBOS
(4800)
or
A-C2D05 (4COO)
'- File In Use'
for the
failing
LED
on
the
logic board (MIM 501).
Up
light: Off
Down light: On
Are the lights correct?
Y N
054
- Defective
Diskette/Main MPU
card (A-Cl)
(MIM 303).
If a 'Ros
Patch'
cable
;s
connected to the card,
GO TO MAP 0600,
ENTRY POINT A.
055
- There
;s
an open or short ;n
this line,
use
MIM
313
and
Logic
Diagram
LDOl-3
to
isolate the failure.
056
- There is
no
problem
with
the
'Drive In Use' LEDs.
GO TO MAP 2000, ENTRY POINT A.
EC840874
MAP 2280-6

Advertisement

Table of Contents
loading

This manual is also suitable for:

5285