IBM 5280 Manual page 138

Distributed data system programmable data station maintenance analysis procedures
Hide thumbs Also See for 5280:
Table of Contents

Advertisement

A A A
P
Q
R
I I I
1 ,I 1
083
DATA ENTRY MAP
MSR
PAGE
12 OF
14
-
Defective
MSR
card (A-Bl)
(MIM 501, 771).
084
-
Defective
(MIM 761).
085
Reader
- Probe
A-B2B04,
501) .
Assembly
paR'
( 1'1IM
Install
a
A-Cl-TP-040,
jumper
from
ground (MIM 303).
Up
light: Off
Down light: On
Test paR',
to
Are the lights correct?
Y N
086
Defective Disk/Main MPU
Card
(A-Cl)
(MIM 303, 501).
-
If
a
'Ros
Patch'
cable is
connected to the card,
GO TO MAP 0600, ENTRY POINT A.
087
-
Leave probe on A-B2B04,
,
POR'"
<MIM 501).
Remove
the
A-CI-TP-040,
ground (MIM 303).
Up
light: On
Down light: Off
jumper
-from
Test POR',
to
Are the lights correct?
Y N
A A
S T
A A
S T
MAP 1030-12
088
Power off.
Set the CE meter to
the
RXI
scale.
Connect
A-B2B04~
and
the
ground.
the positive lead to
' - POR'
(MIM
531),
negative
lead
to
Is the meter reading 30 ohms or
above?
Y N
089
-
Leave
the
meter connected
as in the previous step.
-
Use the net list (MIM 531).
Remove
each
card
in
the
net,
one
at a t'ime, until
the meter reads 30 ohms
or
above.
Replace
the
last
card
removedo
If all the cards in the net
have
been
removed and the
meter
reading
is
still
below 30
ohms,
suspect
a
ground on the Logic Board.
090
Defective
Diskette/Main
MPU
Car d (A- C 1) 0-11 M 303, 5 0 1 ) .
If a
'Ros
Patch'
cable
is
connected to the card,
GO TO MAP 0600, ENTRY POINT A.
091
Probe
A-B2B02,
(MIM 531).
'1
MHz Clock'
Up
1; ght: On
Down light: On
Are the lights correct?
Y N
EC839787
PEC839661
1 1
3 3
A A
U V
MAP 1030-12