IBM 5280 Manual page 235

Distributed data system programmable data station maintenance analysis procedures
Hide thumbs Also See for 5280:
Table of Contents

Advertisement

L M
4 4
COMMUNICATIONS MAP
NON AUTO ANSWER
PAGE
5 OF
5
025
Defective
communications
MPU
card (A-ES)(MIM 811).
If
a
'Ros
Patch'
cable
is
connected to the card,
GO TO
MAP
0600, ENTRY POINT A.
026
Remove
the
communications
MPU
card (A-ES)(MIM 811)
Is the line grounded?
Y N
027
Disconnect the internal
cable
from the A-E5-JOl connector.
Use
the
CE
meter on the RXI
scale
to
measure
the
resistance to a ground pin.
A
short will read less
than
20
ohms.
At the POI connector ON
THE
INTERNAL
CABLE,
measure
from
POI-07
'Data
Tip',
to
POl-23
,'Signal
Ground' (MIM
867, probe point E).
Is the line grounded?
Y N
028
Defective communications MPU
card (A-ES)(MIM 811).
If a 'Ros
Patch'
cable
;s
connected to the card,
GO TO MAP 0600,
ENTRY POINT A.
D N P
2
MAP 3013-5
029
- Disconnect
the
external
cable from
the
machine
at
connector J140.
Use
the CE meter on the RXI
scale
to
measure
the
resistance
to a ground pin.
A short will read less
than
20
ohms.
At
the
P140
connector
ON
THE
EXTERNAL
CABLE, measure from
P140-09
'Data
Tip',
to
P140-21
,'Signal
Ground'
(MIM 867,
probe point F).
Is the line grounded?
Y N
030
Defective internal cable.
031
Defective external cable.
032
Defective logic board.
033
Can the constant test
pattern
of
hex
FFFF
be heard at the calling
telephone?
Y N
034
035
Telephone problem
Have the customer place a call
to the telephone company.
The test ;s complete.
Return to the MDIs, answer
'Y',
and follow the prompts.
EC840874
PEC839787
N P
MAP 3013-5