Distributed data system programmable data station maintenance analysis procedures
Hide thumbs Also See for 5280:
Table of Contents

Advertisement

F
3
COMMUNICATION MAP
016
- Measure
Detection
MANUAL CALL
PAGE
4 OF
A-D8BIO
l'
and
'Current Detection 2'.
Is
one
of
these
approximately -3 Vdc?
Y N
017
GO TO PAGE 2, STEP 006,
ENTRY POINT C.
018
Measure
Relay' •
A-D8B03
5
'Current
A-D8B13
signals
'Transfer
Is the signal
approximately
-2.7
Vdc?
Y N
019
Defective
3SLS
Line
Adapter
card (A-D7)(MIM 812).
020
Defective
plate.
World
Remove the jumper
'-
Data
Terminal
A-D7D08 'GND'.
Trade
1 i
ne
from
A-D7B02
Ready'
to
MAP 3017-4
A-DSBIO
'Current Detection l ' and
A-DSBI3
'Current
Detection
2'
signal levels:
On: -3 Vdc
Off:
+1
Vdc
A-D8B03
'Transfer
Relay'
signal
levels:
On: -2.7 Vdc
Off: -4.5 Vdc
The 'Transfer Relay' should be
on
when
the
machine;s in data mode
and the telephone lifted.
EC840874
PECS397S7
MAP 3017-4