IBM 5280 Manual page 97

Distributed data system programmable data station maintenance analysis procedures
Hide thumbs Also See for 5280:
Table of Contents

Advertisement

W
6
DATA ENTRY MAP
A-El DISPLAY
PAGE
7 OF
10
035
- Probe
A-E4D04,
'IS MHz Clock'
(MIM 531).
11_
,~_L..L_
.... _
w~
"'~
•• , " .
V I I
Down light: On
Are the lights correct?
Y N
036
- Probe A-CSB03, '18 MHz Clock'
(MIM 531).
Up
light: On
Down light: On
Are the lights correct?
Y N
037
The 'lS MHz Clock' line
is
failing.
Suspect a shorted
net.
Use the net list (MIM
531)
to
isolate
the
failure.
- -" - - - OR
- Failing
Diskette/Main
MPU
Card (A-Cl) (MIM 303).
If
a
'ROS Patch' cable is
connected to the card,
GO TO t--1AP 0600,
ENTRY POINT A.
03S
- Failing Data Station
Adapter
Card (A-El) (MIM 501).
x
MAP 1011-7
039
- Probe
A-EIS02,
'-
POR'
(MIM
531) •
up
:i,-i gi-d;;
un
Down light: Off
Are the lights correct?
Y N
040
- Failing
Diskette/Main
Card (A-Cl) (MIM 303).
MPU
- If a
'ROS
Patch'
cable
is
connected to the card,
GO TO MAP 0600, ENTRY POINT A.
041
- Probe
A-EIB02,
'-
POR'
(MIM
531).
- Momentarily jumper the '-
Test
POR'
line
at
A-CI-TP-040
to
frame ground (MIM 303).
Up
Ii
ght: On
Down light: Pulses
Are the lights correct?
Y N
042
Failing
Diskette/Main
MPU
Card (A-Cl) (MIM 303).
If a
'ROS
Patch'
cable
is
connected to the card,
GO TO MAP 0600, ENTRY POINT A.
043
- Failing
Data
Station
Adapter
Car d (A- E 1)
(M
I M 501).
ECS40S74
PEC839787
X
MAP 1011-7

Advertisement

Table of Contents
loading

This manual is also suitable for:

5285