Distributed data system programmable data station maintenance analysis procedures
Hide thumbs Also See for 5280:
Table of Contents

Advertisement

Z A
8 A
8
046
COMMUNICATIONS MAP
EIA WRAP ERROR MAP
PAGE
9 OF
12
The EIA line Adapter
card
is
defective (A-D7)(MIM 823).
- -
OR - - - -
I -
The logic board is defective.
047
Power off.
Remove the wrap connector.
Remove
the
EIA
line
adapter
card.
Use
the
CE
meter
on
the RXl
scale to measure the
resistance
for a short to the 'Transmitted'
line.
A
short
will read less
than 20 ohms.
Measure the extra
'Received' line at
probe
point
D.
Is
the
line
shorted to the line
being wrapped?
Y N
048
The wrap connector is defective.
049
Remove the
parts
listed
below
one at a time in the order given
until
the short goes away.
The
last part removed is defective.
The internal cable.
The communications MPU card.
If the short is
still
present,
the logic board is defective.
If
a
'Ros
Patch'
cable
is
connected to the card,
GO TO MAP 0600, ENTRY POINT A.
W
8
050
MAP 3019-9
Remove the internal cable
Probe
the
extra
'Transmitted'
line at probe point E.
~p
::'~Sh"!=:
8 ..
Down 1 i ght: Of-f
Are the lights correct?
Y N
051
The
internal
defective.
052
cable
is
Probe
the
extra
'Transmitted'
line at probe point D.
Up
light: On
Down light: Off
Are the lights correct?
Y N
053
- Defective
communications
MPU
card (A-E5)(MIM 811).
If
a
'Ros
Patch'
cable
is
connected to the card,
GO TO MAP 0600, ENTRY POINT A.
054
Probe
the
extra
'Transmitted'
line at probe point C.
Up
light: On
Down light: Off
Are the lights correct?
Y N
055
- The logic board is defective.
1
o
A
B
EC840874
PEC839787
MAP 3019-9