IBM 5280 Manual page 181

Distributed data system programmable data station maintenance analysis procedures
Hide thumbs Also See for 5280:
Table of Contents

Advertisement

F G
2 2
DRIVE MAP
MIN CONF SYS
PAGE
3 OF
6
014
Defective
PTX
(Diskette
MIM
375) .•
- - - -
OR
Defective
LED
(Diskette
MIM
371).
015
Do
the
Diskette
Speed service
check (Diskette MIM 367).
Was a problem observed when
doing
this service check?
Y N
4
016
Power Off.
Carefully
move
the
Head/Carriage
on the drive to
the innermost track.
Observe to see if the
stepper
motor
pulley
and
drive band
are tight
and
are
operating
correctly.
If
not
see
the
Diskette
HIM's
for
the
adjustment
procedur.es.
or
replacement
Power On.
Observe the
Head/Carriage
on
the drive.
Does the Head/Carriage access to
the outermost track?
Y N
017
Defective
Stepper
Motor
(Diskette HIM 357).
H
J
J
HAP 2270-3
018
Do the Head
Load
Solenoid
and
Bail service check (Diskette HIM
343) •
Was
a problem observed when doing
this service check?
Y N
4
K
019
Preform the Drive Band service
check (Diskette MIM 361).
Preform
the
Head/Carriage
service
check
(Diskette
HIM
337) .
Was
a
problem
observed
when
doing these service checks?
Y N
020
021
Defective Head/Carriage
assembly (Diskette MIM 341).
- - - - OR - - - - -
Defective cable between
the
Diskette
Drive Control card
and
the
Diskette/Main
MPU
card (MIM 313).
Can the system be IPL'ed now?
Y N
022
Defective Head/Carriage
assembly (Diskette MIM 341).
023
- End
of
call.
Run 'SYSTEST'
before returning the system to
the Customer (MIM 975).
EC840874
MAP 2270-3

Advertisement

Table of Contents
loading

This manual is also suitable for:

5285