Bosch Rexroth IndraDrive MPH-02 Functional Description page 651

Firmware for drive controllers
Table of Contents

Advertisement

MPH-02, MPB-02, MPD-02
Trigger Edge (P-0-0030)
DOK-INDRV*-MP*-02VRS**-FK01-EN-P
Handling, Diagnostic and Service Functions
trigger level
(P-0-0027)
time resolution
(P-0-0031)
start of recording
(P-0-0028, bit 0)
recording active
(P-0-0029, bit 0)
trigger start
(P-0-0029, bit 1)
number of valid measured
values (P-0-0150)
signal > trigger level
(P-0-0029, bit 8)
signal < trigger level
(P-0-0029, bit 9)
internal trigger
(P-0-0037, bit 0)
trigger control offset
(P-0-0035)
external trigger signal
(P-0-0036)
trigger function completed
(P-0-0029, bit 3)
no. of measured val. after
trigger event (P-0-0033)
delay function completed
(P-0-0029, bit 4)
Fig. 10-30: External trigger with offset measurement (P-0-0028; bit 1 = 1)
Note:
The use of the external trigger source with trigger offset
determination is described in the section "Synchronizing the
Measuring Signals of Several Axes" (see below).
Selecting the Trigger Edges
In parameter P-0-0030, Oscilloscope: trigger edge it is possible to set
at which edge of the trigger signal the "internal trigger" is released. The
following options are available:
• triggering at the positive edge
• triggering at the negative edge
• triggering at both edges
• triggering when trigger signal equals trigger level
See Parameter Description "P-0-0030, Oscilloscope: trigger edge"
trigger edge negative
(P-0-0030; bit 1 set)
end of recording
control signal
status signal
10-69
t
DK000049v01_en.fh7