General Information On The Oscilloscope Function - Bosch Rexroth IndraDrive MPH-02 Functional Description

Firmware for drive controllers
Table of Contents

Advertisement

10-64
Handling, Diagnostic and Service Functions

General Information on the Oscilloscope Function

Sequence of a Measurement/Status Diagram
recording stopped
P-0-0028 bit 0: 1 ® 0
recording not active
P-0-0029 bit 0 = 0
start of recording?
P-0-0028 bit 0: 0 ® 1
internal trigger signal
P-0-0037 bit 0 = 0
valid trigger signal
available (P-0-0026)?
recording active
P-0-0029 bit 0 = 1
P-0-0029 bit 2,3,7 = 0
trigger comparison runs
P-0-0029 bit 1 = 1
trigger condition
external trigger
P-0-0028 bit 1 = 1
kind of trigger?
waiting for external signal
P-0-0029 bit 2 = 1
P-0-0037 bit 0 = 1
external trigger signal
available (P-0-0036)?
YES (bit 0 = 1)
setting trigger bit
P-0-0029 bit 3 = 1
delay function completed
P-0-0029 bit 4 = 1
recording completely terminated
P-0-0028 bit 0 = 0
Fig. 10-27: Status diagram of oscilloscope function
NO
YES
trigger error
P-0-0029 bit 7 = 1
NO
YES
NO
fulfilled?
YES
internal trigger
P-0-0028 bit 1 = 0
setting trigger bits
P-0-0029 bit 2,3 = 1
NO (bit 0 = 0)
delay function active
P-0-0029 bit 4 = 0
P-0-0037 bit 0 = 1
no. of measured
values reached
(P-0-0033) ?
YES
DC000011v01_en.FH7
MPH-02, MPB-02, MPD-02
NO
DOK-INDRV*-MP*-02VRS**-FK01-EN-P

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rexroth indradrive mpb-02Rexroth indradrive mpd-02

Table of Contents