Features

Command Value Processing in Torque/Force Control

Filtering the Command Value
Additive Current Command
DOK-INDRV*-MP*-02VRS**-FK01-EN-P
• torque/force control with regard to the sum of the command values
preset in parameters S-0-0080, Torque/force command value and
S-0-0081, Additive torque/force command value
• The torque/force command value is generated internally by the velocity
loop. The value of parameter S-0-0081 can be added to this command
value as an additive component.
• limitation of the preset command value to limit value that can be
parameterized
• filtering the command value by means of parameter P-0-0176,
Torque/force command smoothing time constant
Pertinent Parameters
• S-0-0080, Torque/force command value
• S-0-0081, Additive torque/force command value
• S-0-0082, Torque/force limit value positive
• S-0-0083, Torque/force limit value negative
• S-0-0092, Bipolar torque/force limit value
• S-0-0109, Motor peak current
• S-0-0110, Amplifier peak current
• S-0-0111, Motor current at standstill
• P-0-0001, Switching frequency of the power output stage
• P-0-0038, Torque-generating current, command value
• P-0-0049, Effective torque/force command value
• P-0-0051, Torque/force constant
• P-0-0109, Torque/force peak limit
• P-0-0176, Torque/force command smoothing time constant
• P-0-4046, Effective peak current
Pertinent Diagnostic Messages
• A0100 Drive in TORQUE control
• F8079 Velocity limit S-0-0091 exceeded
See also below "Command Value Processing in Torque/Force Control"
See also below "Current Loop"
The command value preset by S-0-0080, Torque/force command value
is filtered by a PT1 filter. The time constant of the filter can be changed by
means of P-0-0176, Torque/force command smoothing time constant.
In addition, it is possible to add an unfiltered additive command value via
Value
S-0-0081, Additive torque/force command value. If required, this value
can be cyclically configured.