Connecting the device
8.2 Electrical connections
8.2.4

Connecting the signal cables

Overview
Figure 8-6
Procedure
1. Undo the six screws
2. Remove the shielding plate
3. Strip the end of signal cable to a length of approx. 1 cm.
4. Loosen the union nut from the respective cable gland
mounted device.
92
Screws for door
Shielding plate
Cable glands for signal lines (7 pieces)
Power supply cable gland
Wall-mounted device, connecting signal cables
and open the door of the wall-mounted device.
on the right side panel. To do this loosen the screws.
Operating Instructions, 05/2018, A5E31930403-06
on the underside of the wall-
Wall-mounted device