Preparing for installation
Figure 7-11
1. Isolate the device from power.
2. Loosen the six screws and open the door.
3. Loosen the three screws
4. Loosen the screw
the bottom of the enclosure.
5. Remove the cable gland plate including the "Standard" terminal block
Wall-mounted device
Operating Instructions, 05/2018, A5E31930403-06
Installing / removing and connecting analyzer and option modules
Screw shield plate
Screw, cable gland plate
Shielding plate signal lines
Removing the cable gland plate
on the inside of the right side panel and the eleven hex nuts
Screw shield plate
"Standard" terminal block on the cable
gland plate
Hexagon nut (11 units)
,
and
and remove the shield plate for signal cables
7.7 Installing option modules
.
.
at
73