Connecting Protruding Cables; Thread Sizes In The Terminal Box; Internal Equipotential Bonding - Siemens SIMOTICS XP 1MB 1 Series Operating Instructions Manual

Low-voltage motors
Table of Contents

Advertisement

Damage to connecting cables that are freely led out
You must observe the following note to avoid damaging connecting cables that are freely led
out:
• It must be ensured that there are no foreign bodies, dirt, or moisture in the terminal base
• Use O-rings or suitable flat gaskets to seal entries in cover plates (DIN 42925) and other
• Seal the terminal base of the machine enclosure using the original seal of the cover plate to
• Please observe the tightening torques for cable entries and other screws.
6.1.4.7

Connecting protruding cables

In the case of connection cables brought out of the machine, no terminal board is installed on
the terminal base of the machine housing. The connection cables are directly connected to
stator winding terminals at the factory.
The connection cables are color-coded or labeled. The customer directly connects individual
cables in the control cabinet for their system in accordance with the labeling.
6.1.4.8

Thread sizes in the terminal box

Thread size for additional glands, e.g. PTC thermistor or anti-condensation heating M16x1.5
or M20x1.5
Deviating thread sizes are specified at the motor.
6.1.4.9

Internal equipotential bonding

The internal equipotential bonding between the grounding terminal in the terminal box, the
terminal box components and the machine enclosure is ensured via metallic contact, a copper
braided strip or a stranded wire.
1MB..1/2/3/4 - shaft heights 63 ... 355
Operating Instructions, 11/2023, A5E52779900A
CAUTION
of the machine enclosure.
open entries.
prevent dust and water from entering.
Shaft height
63 ... 90
100 ... 132
160 ... 180
200 ... 225
250 ... 315
355
6.1 Connecting the machine
Threaded entry
Size
M16 x 1.5
M25 x 1.5
M32 x 1.5
M40 x 1.5
M50 x 1.5
M63 x 1.5
M80 x 2
Electrical connection
Quantity
1
2
2
2
2
2
83