Filtering the Closed-Loop Traction Circuit (continued)
Hydraulic System: Service and Repairs
g217797
1.
Traction pump
2.
Left elbow fitting
3.
Hydraulic hose (reverse)
3. Clean the junction of the hydraulic hose and 90° hydraulic fitting at the bottom
of the traction pump
4. Connect the Toro high flow hydraulic filter in series between the traction
pump fitting and disconnected hose. Use the hydraulic hose kit (refer to
Hydraulic Hose Kit (page
that the fitting and hose connections are properly tightened.
Using other hydraulic fluids could damage the hydraulic system.
Use the hydraulic fluids that are specified in the Operator's Manual.
5. After you install the high-flow filter to the machine, check and fill the hydraulic
tank with the correct quantity of new hydraulic fluid.
6. Start the engine and run it at low-idle speed. Check for hydraulic-fluid leaks
at the filter and hose connections. Correct any leaks before you proceed.
During this procedure, all the wheels will be off the ground and
rotating.
Ensure that the machine is well supported so it will not move and
accidentally fall to prevent injuring anyone around the machine.
Figure 143
4.
Hydraulic hose (forward)
5.
Right elbow fitting
(Figure
143). Disconnect the hose from the pump fitting.
6–45)) to connect the filter to the machine. Ensure
IMPORTANT
CAUTION
Page 6–150
Reelmaster
®