Flushing The Hydraulic System - Toro Reelmaster 5410 Series Service Manual

Models with infocenter display
Hide thumbs Also See for Reelmaster 5410 Series:
Table of Contents

Advertisement

Priming the Hydraulic Pumps (continued)

Flushing the Hydraulic System

Reelmaster
®
5410/5510/5610 Series
15216SL Rev C
(traction) pump have sufficient fluid during initial start-up and running. The
pumps can be primed by using a remote starter switch (refer to
Switch (page
6–49)) to crank the engine which allows the pumps to prime.
Use the following procedure to prime the hydraulic pumps:
1. Ensure that the key switch is in the O
from the key switch.
2. Check the hydraulic-fluid level in the hydraulic reservoir and add correct
quantity of fluid if necessary; refer to the Operator's Manual.
g193733
1.
B+ terminal
Note: A blue wire connects to the starter motor solenoid B+ terminal
142). It is not necessary to remove this blue wire from the solenoid terminal
for hydraulic pump priming.
3. Connect the remote starter switch electrical leads to the starter motor
solenoid B+ terminal and positive post of the battery.
4. Engage the remote starter switch and crank the starter for 30 seconds to
prime the hydraulic pumps. Wait for 30 seconds to allow the starter motor and
starter solenoid to cool. Repeat the cranking procedure for the second time.
5. Disconnect the remote starter switch leads from the starter motor solenoid
terminal and positive post of the battery.
Flush the hydraulic system whenever there is a severe component
failure or the system is contaminated (for example, the fluid appears
milky, black, or contains metal particles).
position and the key is removed
FF
Figure 142
2.
Starter solenoid
IMPORTANT
Page 6–147
Remote Starter
3.
Starter motor
Hydraulic System: Service and Repairs