Activate/Deactivate Adaptation (Cadapton, Cadaptof) - Siemens SINUMERIK 840D sl Programming Manual

Nc programming
Hide thumbs Also See for SINUMERIK 840D sl:
Table of Contents

Advertisement

Work preparation
3.15 Axis functions
Read parameter set number
The number of the selected parameter set (specified parameter set) can be read via the system
variable $AA_SCPAR.
3.15.8

Activate/deactivate adaptation (CADAPTON, CADAPTOF)

Using the predefined CADAPTON() and CADAPTOF() procedures, predefined adaptations for
adjusting the dynamic response or control parameters can be activated, updated and
deactivated from the part program. They are also used in CYCLE782 (Page 1091).
Syntax
...
CADAPTON(<Result>,<Axis>,<InVar>[,<InValue>])
...
CADAPTOF(<Result>,<Axis>,<InVar>)
...
Meaning
CADAPTON():
CADAPTOF():
<Result>:
<Axis>:
886
Activates adaptation relationship
Deactivates adaptation relationship
Note:
Ignore active adaptation relationship (MD16501 = 1) CADAPTOF(), a previously pro‐
grammed input value (<InVal>) remains active.
Result variable: Return value for the status (called by reference parameter)
Data type:
INT
Value:
0
No error
1
No valid adaptation table parameterized
2
<Axis> parameter invalid
3
<InVar> parameter invalid
4
Reserved
5
<InVal> parameter invalid
Machine axis name of the input axis of the adaptation relationship
Data type:
AXIS
Range of
Machine axis names defined in the channel
values:
Note:
Using this parameter, those adaptations are addressed, which, in MD16504
$MN_CADAPT_INPUT_AX, entered a value corresponding to parameter <Axis>.
The other <InVar> and <InVal> parameters are assigned to this axis.
Programming Manual, 12/2019, 6FC5398-2EP40-0BA0
NC programming

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinumerik 840de sl

Table of Contents