Siemens SIRIUS M200D Manual page 211

Industrial controls, load feeders and motor starters, profibus / profinet
Hide thumbs Also See for SIRIUS M200D:
Table of Contents

Advertisement

Object
Byte.Bit
Parameters / content
No.
26
39.0 ... 3
Input 1 – action
NO contact/NC contact
NO contact/NC contact
NO contact/NC contact
NO contact/NC contact
NO contact/NC contact
NO contact/NC contact
NO contact
NO contact
NO contact
NO contact/NC contact
NO contact
NO contact
28
39.4 ... 7
Input 2 – action
NO contact/NC contact
NO contact/NC contact
NO contact/NC contact
NO contact/NC contact
NO contact/NC contact
NO contact/NC contact
NO contact
NO contact
NO contact
NO contact/NC contact
NO contact
NO contact
30
40.0 ... 3
Input 3 – action
NO contact/NC contact
NO contact/NC contact
NO contact/NC contact
NO contact/NC contact
NO contact/NC contact
NO contact/NC contact
NO contact
NO contact
NO contact
NO contact/NC contact
NO contact
NO contact
32
40.4 ... 7
Input 4 – action
NO contact/NC contact
NO contact/NC contact
NO contact/NC contact
NO contact/NC contact
NO contact/NC contact
NO contact/NC contact
NO contact
NO contact
NO contact
NO contact/NC contact
NO contact
NO contact
M200D PROFIBUS/PROFINET
Manual, 08/2014, A5E01577426A/RS-AA/004
Range of values
[0] No action
[1] Tripping without restart
[2] Tripping with restart
[3] Trip end position CW
[4] Trip end position CCW
[5] Group warning
[6] Manual local mode
[7] Emergency start
[8] Motor CW
[9] Motor CCW (on RS only)
[11] Quick stop
[12] Trip reset
[13] Cold start
[0] No action
[1] Tripping without restart
[2] Tripping with restart
[3] Trip end position CW
[4] Trip end position CCW
[5] Group warning
[6] Manual local mode
[7] Emergency start
[8] Motor CW
[9] Motor CCW (on RS only)
[11] Quick stop
[12] Trip reset
[13] Cold start
[0] No action
[1] Tripping without restart
[2] Tripping with restart
[3] Trip end position CW
[4] Trip end position CCW
[5] Group warning
[6] Manual local mode
[7] Emergency start
[8] Motor CW
[9] Motor CCW (on RS only)
[11] Quick stop
[12] Trip reset
[13] Cold start
[0] No action
[1] Tripping without restart
[2] Tripping with restart
[3] Trip end position CW
[4] Trip end position CCW
[5] Group warning
[6] Manual local mode
[7] Emergency start
[8] Motor CW
[9] Motor CCW (on RS only)
[11] Quick stop
[12] Trip reset
[13] Cold start
A.1 Data formats and data sets
Increment
Default
setting
[0]
[0]
[0]
[0]
Appendix
Relevant for
All starters
All starters
All starters
All starters
211