Clearing Signaling Server Faults - Nortel 1000E Maintenance Manual

Communication server
Hide thumbs Also See for 1000E:
Table of Contents

Advertisement

Clearing Signaling Server faults

Table 13
Signaling Server Diagnosis (Part 1 of 2)
Condition
Signaling Server not
running. All LEDs off.
Signaling Server running
with no fan noise
Floppy drive tries accessing
floppy but fails
Floppy drive not accessing
floppy & green light not
illuminating.
CD-ROM drive tries to
access CD-ROM but stops
CD-ROM drive not
accessing CD-ROM. No
green light.
100BT light not on
The Signaling Server is a commercial one-use server that provides signaling
for the CS 1000E system. It has ELAN and TLAN network interfaces, which
are connected to an Ethernet switch through CAT 5 cables. It has two serial
ports and visual indicators for maintenance. It has three push buttons, one
each for power, reset, and INI (initialization). The INI button, USB ports,
keyboard port, and mouse port are not supported.
Possible Cause
No power to system
Power supply failed
Fan failed
Floppy media is corrupted
Floppy not formatted
Floppy drive failed
CD-ROM media is corrupted
CD-ROM Drive failed
Auto Negotiate Failed
Clearing faults
Action
Check power cable
Replace Signaling Server
Replace Signaling Server
Replace floppy
Format floppy
Replace Signaling Server
Replace CD-ROM disk
Replace Signaling Server
Provision Ethernet Switch to
100MB. Switch Auto Negotiate
off.
Communication Server 1000E
Page 75 of 162
Maintenance

Advertisement

Table of Contents
loading