Replacing the NTDK20 SSC card

5
Software-enable the card by entering:
ENLC c
When the process is complete, a system response will appear.
End the session:
**** (star symbols)
To replace the NTDK20 SSC card, minimum vintage HA, follow the steps in
Procedure 19.
Procedure 19
Replacing the NTDK20 SSC card
1
Perform an EDD backup in LD 43.
2
Turn the Media Gateway power supply off.
3
Hold the NTDK20 SSC circuit card by the lock latches, unlock the latches,
and slide the circuit card out of the Media Gateway.
4
Remove the software daughterboard. Install the software daughterboard
and the security device on the replacement NTDK20 SSC card.
Refer to "Replacing the NTTK25 Software Daughterboards" on
5
Transfer any IP daughterboards used to the replacement NTDK20 SSC:
NTDK83
NTDK99
Refer to "Replacing IP daughterboards" on
6
Hold the NTDK20 SSC circuit card by the lock latches and slide it into slot
0 of the Media Gateway until it connects with the backplane.
7
Secure the lock latches on the circuit card.
8
Set the breaker on the Media Gateway power supply to the on position.
Replacing equipment
End of Procedure