Replacing equipment
5
Pull the power supply out of the Call Server. (See Figure 13)
Figure 13
Power supply module
6
Before you insert the power module into the Call Server, set the power
supply switch on the rear of the module to OFF (down).
7
Insert the replacement power supply into the vacated slot and ensure it is
well-seated.
8
Use a Phillips screwdriver to tighten the locking screw on the power
supply.
9
Reattach the power cord at the rear of Call Server and reconnect to the
power source. Turn on power to the power supply module.
10 Tag defective equipment with a description of the problem, and package
it for return to a repair center.
September 2004
End of Procedure