Nortel 1000E Maintenance Manual page 57

Communication server
Hide thumbs Also See for 1000E:
Table of Contents

Advertisement

Table 9
Programs used in Midnight and Background Routines (Part 1 of 2)
LD
30
33
35
36
37
38
40
43 (Midnight only)
44
46
60 (Midnight only)
61 (Midnight only)
A memory test runs once a day. The Core Equipment Diagnostic (LD 35)
runs as part of the Midnight Routine, even if it is not programmed.
The Background Routine runs when no other program is loaded in the overlay
area. The programs included in the Background Routine run in sequence
repeatedly until there is another request to use the overlay area (for example,
if users log on to check the status of a circuit card) or the Midnight Routine
runs.
For the CS 1000E system, include the programs listed in Table 9 in Midnight
and Background Routines. Software Audit (LD 44), and Network and
Signaling Diagnostic (LD 30) should always be used in the Background
Routine.
The maintenance requirements and the configuration of the system determine
the other programs included in Midnight and Background Routines.
Program function
Network and Signaling Diagnostic
1.5 Mbit/s Remote Peripheral Equipment Diagnostic
Core Equipment Diagnostic
Trunk Diagnostic 1
Input/Output Diagnostic
Conference Circuit Diagnostic
Call Detail Recording Diagnostic
Data Dump
Software Audit
Multi-frequency Sender Diagnostic
Digital Trunk Interface Diagnostic
Message Waiting Lamp
Software maintenance tools
Communication Server 1000E
Page 57 of 162