Replacing The Ntdu65 Power Supply Module - Nortel 1000E Maintenance Manual

Communication server
Hide thumbs Also See for 1000E:
Table of Contents

Advertisement

Replacing the NTDU65 power supply module

Figure 12
Alarm/fan module
3
Insert the replacement alarm/fan module into the vacated slot and hook
the locking devices.
4
Use a Phillips screwdriver to tighten the screws on the alarm/fan module.
This section describes how to replace the Call Server power supply module.
Procedure 10
Replacing the NTDU65 power supply module
1
Turn off power to the Call Server using the switch located at the rear right
of the Call Server.
2
Also at the rear of the Call Server, unplug the power cord.
3
Loosen the locking screw located on the front of power supply.
4
Unseat the power supply module by pulling on the module handle.
Replacing equipment
End of Procedure