Table 8
Unsupported Overlay commands for MG 1000E
LD
30
32
34
38
45
46
92
Error Monitor
However, a number of maintenance commands are either not supported or not
applicable to the MG 1000Es. Table 8 lists the commands that are not
supported in the MG 1000Es.
Unsupported commands
CPED, DISL, ENLL, LDIS, LENL, LOOP, RPED, SLFT, STEI, TIET,
TTSM, and TTWI
DISL, DISN, DLIF, DSCT, DSNW, DSPS, DSRB, DSTS, DSXP,
ENLG, ENLL, ENLN, ENNW, ENPS, ENRB, ENTS, ESTU, FDIS,
PCON, PERR, PLOG, PMES, PTAB, PTRF, RLBT, RLSU, SDLC,
STAT NCAL, STAT loop, STAT NWK, STAT PER, IDC loop, IDCS,
SUPL, XNTT, XPCT and XPEC
DTR and TDS
Also, the following Maintenance Telephone commands are not
supported:
CDT, CMP, CUST, CWG, DRNG, DTD, ITN, JDRG, JIDT, ORD,
PCRT and TST
DISX and ENLX
TEST
DISL, DISX, ENLL, ENLX and MFS
No supported commands (the Automatic Trunk Maintenance feature
is not supported in CS 1000E)
The Error Monitor is a resident program which continuously tracks call
processing. The Error Monitor generates system messages if it detects invalid
or incorrectly formatted call processing information.
System messages generated by the Error Monitor are preceded by the
mnemonic ERR, which usually indicates hardware faults, or the mnemonic
BUG, which usually indicates software problems.