Connecting

5.7 Connecting DRIVE-CLiQ components

4. Tighten the mounting screw.
5. Plug the screw terminal with cables into the X124 connection.
Reverse polarity protection
The LED "RDY" lights up green when the power supply is connected correctly and switched
on.
Note
The control does not run if the polarity is reversed. However, integrated reverse polarity
protection protects the electronics from damage.
Fuse
If the control is defective, an internal fuse protects the electronics from consequential
damage (e.g., fire). In this case, the module must be replaced.
5.7
Connecting DRIVE-CLiQ components
DRIVE-CLiQ connects the components in the SINAMICS S120 drive family as well as
SIMOTION D410. DRIVE-CLiQ is a communications system, which enables
SIMOTION D410 to automatically detect connected components. DRIVE-CLiQ provides a
wiring tree, the topology of which can be visualized in SIMOTION SCOUT.
You will find information on the components that can be connected to DRIVE-CLiQ in the
section DRIVE-CLiQ interface (Page 38).
Rules for wiring DRIVE-CLiQ
The following rules must be followed for wiring DRIVE-CLiQ:
● Ring wiring is not permitted.
● Components must not be double-wired.
Connecting DRIVE-CLiQ components
Connect the SIMOTION D410 X100 socket to the corresponding sockets on the drive
components using the DRIVE-CLiQ signal cable (motor with DRIVE-CLiQ interface, TM and
SMx modules).
Note
Please note that SIMOTION D410 components in booksize format (CX32 Controller
Extension, Motor Modules, Line Modules, etc.) are not supported.