Operation (hardware)

2.2 Operator controls

2.2
Operator controls
2.2.1

Service and operating mode switches

DIP switches
The SIMOTION D410 features operating mode and service selector switches at the bottom
of its front side (see Overview of operator controls and indicators (Page 27)). These function
using a DIP switch (DIP = Dual In Line Package), where:
● switches S1 to S3 set the operating mode and
● switches S4 to S7 select the service functions
During "normal" operation, the switch settings shown in the figure below must be retained.
Figure 2-2
The modes and service functions that can be set are outlined below.
Mode selector switches
The table shows the possible settings for the mode selector switches.
Table 2- 1
Mode selector switch settings
Operating
S1
S2
mode
RUN
1
1
(three switches =
ON)
STOPU
110 / 101 / 011
(two switches =
ON)
28
DIP switches (factory setting)
S3
Meaning
1
SIMOTION D410 runs the user program and all connected system performances:
Read process image of inputs.
Execution of the user programs assigned to the execution system.
Write process image of outputs.
The technology packages are active in this state. They can execute commands from the
user program.
SIMOTION D410 does not run a user program.
The technology packages are active. Test and commissioning functions can be
executed. The user program is not active.
The I/O modules are in a secure state, i.e. the digital outputs have the status "LOW"
and the analog outputs are at zero current/voltage.
SIMOTION D410
Manual, 02/2012