Interface assignments
Table 3- 16
Interface assignment X120
View
This is the second temperature channel (T2), which depending on the parameterization, is used as a single channel or
1)
in combination with the first temperature channel (T1, see X23).
The EP terminals must be wired on the Power Module on chassis units.
2)
NOTICE
The KTY and PTC temperature sensor must be connected with the correct polarity.
Further information on the temperature sensors can be found in the following literature:
Literature: /IH1/ SINAMICS S120, Commissioning Manual, Chapter "Temperature sensors
for SINAMICS components."
Risk of electric shock!
Only temperature sensors that meet the electrical separation specifications contained in
EN 61800-5-1 may be connected to terminals "+Temp" and "-Temp". If safe electrical
separation cannot be guaranteed (for linear motors or third-party motors, for example), a
Sensor Module External (SME120 or SME125) or Terminal Module TM120 must be used.
If these instructions are not complied with, there is a risk of electric shock!
SIMOTION D410
Manual, 02/2012
Pin
Name
1
Reserved, do not use
2
Reserved, do not use
3
G
4
+ Temp
1)
5
- Temp
1)
6
Reserved, do not use
7
EP +24 V
2)
8
EP M1
2)
DANGER
3.7 EP terminals/temperature sensor connection
Description
Ground
KTY or PTC input
Ground for KTY or PTC
Safety Integrated Basic Functions (+)
Safety Integrated Basic Functions (-)
Interfaces
49