With power OFF
The Control Unit clock continues to operate with the POWER OFF for the duration of the
battery backup time (excluding software clock). The buffer is recharged in the POWER ON
state. If the real-time clock backup time is exceeded, the time is reset. If the
SIMOTION D410 is reset to its factory settings, the clock is also reset to the "default setting
when delivered".
6.7
Shipping and storage conditions
The following information applies to modules transported and stored in the original
packaging.
Table 6- 16
Type of condition
Free fall, checked according to
DIN EN60721-3-2, Class 2M2
Permissible ambient temperature
during storage and transport
Atmospheric pressure
Relative humidity
6.8
Mechanical and climatic ambient conditions
Conditions of use
SIMOTION D410 is designed for use in stationary, weather-protected locations. The
conditions of use exceed the requirements of the environmental test according to
DIN IEC 60068-2-2.
SIMOTION D410 meets the conditions of use, Class 3C3, according to DIN EN 60721-3-3
(operating locations with high traffic densities and in the immediate vicinity of industrial
equipment with chemical emissions).
SIMOTION D410
Manual, 02/2012
Shipping and storage conditions
Permissible range
≤ 1 m
-40° C to +70° C
700 to 1060 hPa (equals a height of up to 3000 m)
5% to 95%, without condensation
Technical data
6.7 Shipping and storage conditions
85